Air insulated ring network cabinet is a term corresponding to compact gas insulated ring network cabinet. In the early days, air insulated ring network cabinets used VEI vacuum or compressed air load switches, gas producing load switches, and other ring network cabinets. Later, with the widespread use of SM6, it became the main stream of air insulated ring network cabinets. Like other air ring network cabinets, the load switch has been replaced with an SF6 air bag type, which means that the load and grounding three-position switch is installed inside an epoxy resin cast insulation shell. SF6 as arc extinguishing and insulation medium

Popis

Fully sealed HV GIS Gas SF6 Insulated Switchgear

Our inflatable SF6 metal seal full insulation series ring network switch cabinet has passed the type test of the national occlusal electrical testing center. Widely used in 10KV/6K power distribution system, it is the preferred switch product for various users in urban and rural areas.

Inflatable ring SF6 cabinet is divided into non-expandable standard configuration and expandable standard configuration. Due to the combination of full module and half module and its own scalability, it has extremely special flexibility. SF6 inflatable ring cabinet implemented GB standard. Under the condition of the interior (20 degree ) run the design life of more than 30 years.

(1) Suitable Altitude: Less than or equal to 2000mSuitable

(2) Temperature: -40 degree ~ plus 55 degree Relative

(#) Humidity: Daily mean Less than or equal to 95 percent , monthly mean Less than or equal to 90 percent

(4) Gradation of Earthquake Damage: Less than or equal to Level 8

Air insulated ring network cabinet - expandable SF6 ring network cabinet, can be freely combined, has a small size, is safe and reliable, and does not require maintenance.

SF6 gas is used as insulation and arc extinguishing medium, and the constant magnetic field arc rotation method ensures strong arc extinguishing ability, good breaking performance, low overvoltage, long electrical life, and maintenance free arc extinguishing chamber.

The load switch - fuse combination electrical appliance has a three position function, perfect sealing, reliable operating mechanism and locking.

The grounding switch has a short-circuit closing function.

96 hour salt spray test conducted by the institution.

1) Load switch

Load switches have a certain on-load breaking capacity, which means they can be energized to open and close under light loads, but they cannot be operated frequently. Generally, load switches are equipped with fuses and have stronger arc extinguishing ability than isolation switches.

2) Isolation switch

3) Circuit breaker

4) Grounding switch

The grounding switch of the high-voltage distribution cabinet is generally grounded on the output load side. When repairing the load side of the high-voltage distribution cabinet (such as tightening bolts, disassembling cables, etc.), we need to disconnect the switch and close the grounding switch of the distribution cabinet at the same time. This can prevent sudden power calls from causing electric shock accidents, and also discharge the remaining charge, which is beneficial for maintenance safety

(1) Misoperation and refusal to operate faults. Such faults may be caused by mechanical faults in the transmission system and operating mechanism, or by electrical control and auxiliary circuit problems; The mechanical faults of the operating mechanism and transmission system are mainly manifested as mechanism jamming, component deformation, displacement or damage, loose and stuck opening and closing iron core, loose shaft pin, tripping failure, etc. Electrical control and auxiliary circuit faults are manifested as poor contact in the secondary wiring, loose terminals, incorrect wiring, burning of the opening and closing coils due to stuck mechanisms or poor transfer switches, ineffective switching of auxiliary switches, as well as faults in operating power supplies, closing contactors, microswitches, etc.

(2) Breaking and closing faults. This type of fault is caused by the circuit breaker body, and for low oil circuit breakers, it mainly manifests as fuel injection short circuit, arc extinguishing chamber burning loss, insufficient breaking capacity, and explosion when closed. For vacuum circuit breakers, it manifests as air leakage in the arc extinguishing chamber and bellows, reduced vacuum, and reignition of the capacitor bank. Cracking of ceramic pipes, etc.

(3) Current carrying fault. This type of fault is mainly caused by poor contact of the isolation plug in the switchgear, which leads to contact melting;

(4) Insulation fault. This mainly includes inter phase or phase to ground short circuit of the busbar, discharge between the busbar and the bushing, discharge of dynamic and static contacts, and hidden danger discharge in the cable compartment. The typical types of faults are external insulation to ground flashover, internal insulation to ground flashover, inter phase insulation flashover, lightning overvoltage flashover, porcelain bushing, capacitor bushing flashover, pollution flashover, breakdown, explosion, lifting rod flashover, CT explosion, breakdown, flashover, Broken porcelain bottles, etc.

(5) External forces and other faults. This includes impacts from external objects, natural disasters, and short circuits caused by animals.

SF6

20230427155105

20230427155118

SF6

XGN15-12 SF6

product-1200-588

Air-insulated-switchgear

product-960-1274

CQC

product-800-600

A

2

baozhuang

product-752-497

Q5 : Is OEM/ODM available?

 

Q6 : You are manufacturer or trading company?
A: We are factory, As a 100 percent professional manufacturer with 20 year's manufacturer experience, we could produce products according to customers' requirements and we could also control the quality of products 100 percent .

 

Q7 : Can the price be negotiated?

 

Q8 : How about inspection?

 

Q9 : What is payment terms?

A: T.T, Paypal,Western Union,Alibaba trade assurance and L/C is acceptable. 30 percent T/T in advance ,70 percent balance before shipment.

 

Q10 : What is the service offered by company?

We also have the sales team to offer good service from pre-sale to after-sale.

product-808-808

 



 

7.1
1.0 -
2.0 - Vacuum /SF6 SF6
2.1 Vacuum /SF6 SF6
2.2
3.0 -
4.1 11 11
4.2 12 12
4.3 50 50
4.4 28 28
4.5 95 95
5.0 A 630 630
5.1 A 630 630
5.2 Jmenovité aktuální (T-OFF) A 125 125
5.3 A 125 125
6.0
6.1 A 630 630
6.4 20 20
6.5 50 50
6.6 Rated Short time current 3 sec 20 20
7.0
1950 1950
1170 1545
750 750